Etiology, pathogenesis, and management of acute intraocular lens opacification: a systematic review

2022-07-30 10:03BitaMomenaeiMohammadRezaAkbariSeyedAliTabatabaeiMohammadSoleimaniMahdiSoleymanzadehKavehFadakarAhmedAlshaheebMahtabMalekpourKhazariYasamanVaseghiKasraCheraqpour
关键词:试件重合盐酸

INTRODUCTION

Millions of cataract surgeries with intraocular lens (IOL)implantation are performed worldwide per year

.Improvement in surgical techniques and manufacturing of biocompatible and foldable IOLs led to excellent postoperative outcomes. Foldable IOLs are synthesized from different materials. Acrylate/methacrylate polymers and silicone elastomers are the two main groups

.

Although cataract surgery brings many advantages to the patients, the risk of various complications is still a concern

.One of the infrequent adverse events that could reduce the patients’ visual acuity and contrast sensitivity is losing the transparency of the IOL

. IOL opacification may lead to IOL removal or exchange, which is unpleasant to both the patient and the surgeon

. A significant proportion of explanted IOLs in an eye center in the United States was secondary to optic opacification or discoloration

. Several reports of acute IOL clouding are available in the literature describing various etiologies of this phenomenon, however, the exact mechanism remained unclear in some cases

. Herein, we aimed to review the causes and outcomes of intraoperative and early postoperative IOL opacification and provide a discussion on prevention from unnecessary IOL explantation in selected individuals.

MATERIALS AND METHODS

The required information was gathered by reviewing various databases including PubMed/Medline, Google Scholar, and Cochrane library, up to September 2021.

We systematically searched the literature using the following keywords: (“intraocular lens opacification” OR “intraocular lens clouding” OR “intraocular lens fogging” OR “intraocular lens discoloration”) AND (“acute” OR “transient” OR “early”OR “reversible” OR “temporary” OR “intraoperative”). No limitations on publication status or study design were imposed.The most relevant papers to IOL discoloration until one month after implantation were collected. The reference list of eligible articles was also explored for additional resources. Finally, all of the selected studies were reviewed.

RESULTS

3.1 本试验采用了一种新型的轴心抗拉试件,采用粘胶法固定受拉端与试件。试验表明,两端端头混凝土与钢板的胶结力大于试件的轴拉力。

Temperature fluctuation Reports of acute IOL clouding immediately after implantation of the IOL into the anterior chamber have been discussed, probably related to the storage condition. Transferring of the IOL from the outside temperature below freezing to the theater shortly before surgery is the common point of these studies. Sudden IOL implantation into the eye with a temperature of 37 ℃ is the hypothesized mechanism of this kind of opacification. The haziness was described in the optic plate’s body without surface deposits and tended to be milky white. Both hydrophilic and hydrophobic acrylic IOLs were affected. The opacity was transient and lasted for less than 24h with spontaneous resolution

.

Adherence to the manufacture’s guidelines regarding the storage temperature of the IOL is recommended to avoid abrupt changes in the temperature and subsequent aforementioned intraoperative IOL clouding. The underlying mechanism is not well known. A previous case report of IOL clouding in an acrylic hydrophilic IOL suggested that the imbibitions of water following a rapid temperature fulctuation is the causal factor

.Zhang

explained a possible cause in which increasing temperature may lead to microbubble production by releasing the air inside the IOL. This causes light refraction, which appears as IOL clouding

. They also hypothesized that the equilibrium in the air dissolution in the IOL and water would lead to resolution of the clouding after a while. Intraoperative opacification of a hydrophilic acrylic with hydrophobic surface IOL following storage in low temperature was described in a case report. The authors performed an

experiment by placing a CT Spheris 504 IOL in a 37℃ balanced salt solution(BSS) after staying at 4℃ for 24h. The same IOL clouding occurred. They mentioned that consolidation of water vapor on a cold surface might explain the observed discoloration, which resolved within 24h

. A previously reported study described a transient AcrySof IOL fogging after warming in a heating cupboard at 47℃ . They used this practice as a way to simplify and facilitate IOL implantation. The lens was clear before folding and the clouding occurred after unfolding into the eye. The IOL was removed and kept dry at room temperature,which led to spontaneously disappearance of opacity after 3h.The reason of the glistening was thought to be the hydration secondary to temperature rise and subsequent microvacuole formation. Dehydration after several hours after keeping the lens in a dry place would cause spontaneous clearing. They also encountered another similar case and therefore advised not to store an acrylic IOL at a temperature above 45℃ .The implant should preferably keep at room temperature to avoid glistening

. A similar glistening formation related to the presumed temperature change of the packaging system’s microenvironment in the first postoperative week was earlier described

.

当然,权衡各种纠纷解决机制,在保护投资者权益方面,应该坚持以诉讼为主导的思路。可以借鉴2003年《最高人民法院关于审理证券市场因虚假陈述引发的民事赔偿案件的若干规定》中的做法,引入有限制的举证责任倒置规则,一定程度上解决投资者举证困难的问题。此外,我国还应尽快出台专门针对金融投资者权益保护的法律法规或司法解释,从而为法官审理案件提供统一的司法依据。

Another published report of early postoperative opacification discussed a patient with cataract and dense vitreous hemorrhage who underwent a triple pars plana vitrectomy,phacoemulsification, and IOL implantation. On the third postoperative day, many small brown corpuscles with the appearance of a dusty haze were seen on the lens surface.The IOL was a single-piece AcrySof acrylic (SA60AT, Alcon,USA). The surgeons explanted and exchanged it with another same type of lens which remained clear. After analysis,proteinaceous material (particularly fragments consisting of 17 aminoacids) was identified on the IOL surface but there was no triamcinolone or calcium. A probable theory is the adherence of the hemocyte element of the residual vitreous hemorrhage to the adhesive AcrySof surface

.

Evaluation of interaction between different IOLs (PMMA,silicone, three-piece hydrophobic acrylic, single-piece hydrophobic acrylic, and single-piece hydrophilic acrylic) and trypan blue 0.1%, fluorescein sodium 2%, and indocyanine green (ICG) 0.5% revealed that only the hydrophilic acrylic materials uptake the dye and get stained. The most significant color change occurred with the use of fluorescein. Careful irrigation of dye can be helpful to avoid lens staining. In addition, the authors do not recommend hydrophilic acrylic IOLs when intraocular dyes are required

.

Olson

later reported the IOL crystallization in 0.07% of cataract surgeries. The previous theory that described Healon GV as the only culprit in the formation of intraoperative crystallization was rejected because some cases were occurred using Amvisc Plus, Occucoat, and other viscoelastics. The degree of crystallization of polymethyl methacrylate (PMMA)IOLs was minimal, and all the significant cases had been noted with silicone IOLs. Correlation with BSS Plus was also statistically significant. The analysis of samples by scanning electron microscopy and X-ray photoelectron spectroscopy showed calcium-containing deposits. They assumed that the osmotic gradient created by using viscoelastic is responsible for calcium deposition on the IOL surface. The authors recommend IOL exchange in terms of encountering to this phenomenon in the operating room

.

Another study in 2006 reported two patients who developed significant granular and crystal-like deposits on the surfaceof single-piece hydrophobic acrylic IOLs immediately after injection into the eye (loaded with Viscoats and Healon GVs, respectively). IOLs were removed and analyzed. They did not find calcium on the surface of lenses and liquid chromatography/mass spectroscopy showed albumin and hemoglobin, which are typically found in aqueous. They hypothesized that crystallization and drying out of OVDs could occur during IOL loading in the cartridge. Various gross appearances could be seen based on the type of viscoelastic used

. Plastic exfoliations from the cartridge may result in intraoperative deposits between the IOL and posterior capsule when the hydrophilic acrylic lens is implanted without viscoelastic

.

Early Postoperative Intraocular Lens Opacification We assessed cases of IOL clouding up to one month after surgery.Here the classifications are provided based on the presumed etiologies. Some of the mentioned underlying pathologies occurred before the IOL implantation but we put them in the postoperative category because no opacity was noted during the surgery. There are different explanations for it. First,elapsing of time is required for interactions to cause visible haziness. Second, there is a possibility of preexisting opacity,which is missed by the surgeon due to poor visualization through a surgical microscope.

Intraocular lens contamination, manufacturing defects,and changing hydrophilicity

The manufacturing process,IOL design, and material are essential features for evaluating the causes of decreasing in IOL transparency. Surgeons and scrub nurses may miss the preexisting haziness of the IOL because of viewing through the surgical microscope with lower magnification and higher illumination in comparison to postoperative slit-lamp examination

. The quality control of all production steps will help to avoid IOL opacification and additional surgery for IOL removal.

Opacification of the silicone optic of an Allergan Medical Optics SI18NB lens was noted seven days after surgery. A nucleus-shaped brown discoloration in the central area was attributed to a material defect and low molecular weight silicone fractions not cross-linked during the manufacturing process. Light scattering from water vapor that diffused into the silicone material in the anterior chamber caused a brown haze.This finding was stable in follow-up visits and did not affect the patient’s visual acuity

. Others stated that the interaction with some intracameral medications, inadequate filtering, or instability of silicone material could lead to discoloration of silicone IOLs

.

隧道工程支护施工技术科学合理准确的使用是保证隧道安全施工作业的基础性条件。大家知道,隧道内部的排水系统的施工难度是非常大的,而且施工的综合性比较强,因此隧道结构防水技术的合理准确的应用要根据施工现场的实际情况而定。通常隧道结构防水的基本原则是“防水、排水、堵水相结合”,常用的施工方法就是在隧道洞的两侧挖掘排水渠、在隧道洞口上方建造截水沟,在隧道内部水沟的出水位置安装保温包头。同时还要密切关注隧道施工缝、变形缝处的排水系统的设计和建造工作。

Another similar event observed with the same IOL, SI-40NB IOL (Allergan) showed a brown haziness the day after surgery.Incubation of the explanted lens in saline at room temperature did not change the opacity after two months. Microscopic examination exhibited numerous abnormal spheroid structures in the central area far from the surface. They hypothesized that it could be related to the chemical compositions of the Allergan silicone IOL or the sterilization process with ethylene oxide gas exposure. The incorporation of water into silicone IOL may be the responsible pathologic phenomenon.Adequate resolution of this type of clouding is unlikely over time, and IOL exchange is often necessary to improve visual function

. However, a case report in 2011 described a diffuse translucent milky white haziness throughout the substance of an AMO Z9002 silicone lens one day after uncomplicated cataract surgery. Clearing of the lens periphery was observed eight days after surgery. The central haze disappeared as well on postoperative day 14. Contamination with industrial chemicals is possible during the manufacturing, sterilization,or packaging process. The mechanism used to explain the initial clearing of the lens periphery was the entrapment of gas or liquid molecules in the lens material and releasing them into the anterior chamber based on the law of diffusion. The peripheral part of the IOL is thinner than the central area. So,less time is required for the diffusion of the contaminants.Besides that, the lens epithelial cells in the capsular bag may have some role in the rapid resolution of opacity in the periphery. A similar pattern of clearing in the same IOL design should be closely visited due to the possibility of spontaneous resolution with excellent visual gain

.

Werner

published data from an analysis of 6 explanted 3-piece silicone lenses due to optic opacification a few hours following implantation. Gross and microscopic studies showed that the IOLs became clear at dry state but whitened during hydration. Gas chromatography/mass spectrometry (GC-MS)analysis was performed. Suspect exogenous chemicals (general classes: terpenes and ketones) were found. These compounds are used in industrial cleaning agents and fumigants. Most IOL packages are semipermeable for the sterilization process.The introduction of contaminants and chemicals through these packages is possible

aerosolizing solutions during the disinfection of the storage rooms. This could result in changes in the material toward hydrophilicity and allowing water entrance after implantation in the eye. Further evaluation revealed that all 6 IOLs were kept in the a same place in Brazil preoperatively

.

Intraoperative Intraocular Lens Opacification Intraoperative IOL opacification is defined as when the surgeon noticed the opacity during the operation. It is responsible for the majority of acute IOL clouding cases in the literature. Different etiologic categories are discussed in the following sections.

(3)一定量的铝分别与一定量的盐酸和NaOH溶液反应,若产生H2的体积比为,则必定是:铝与盐酸反应时,铝过量而盐酸不足;铝与NaOH溶液反应时,铝不足而NaOH溶液过量。

Gray white to faint brown discoloration of an Array SA40N silicone multifocal IOL 1wk after implantation was reported to be related to lens hydration. After 3mo, the patient presented with a blurry vision, which finally led to IOL removal. Light microscopic analysis of the explanted lens was negative for any deposits on or within the IOL material. A chromatographic peak for lidocaine was also noted. Keeping the lens in a dry state resulted in gradual clearing from the peripheral area toward the center. Permeability of the lens material to water and increasing hydrophilicity was attributed to processing defects

.

IOL opacification may have severe adverse effects on visual function and contrast sensitivity

. Several pathologic processes have been proposed for the loss of transparency of the implanted IOLs

. Although no direct cause and effect relationship was demonstrated, knowledge of these different mechanisms and patterns of IOL clouding is essential for cataract surgeons. It could guide them to make the best decision for their patients.

2018年培训内容和形式已逐渐趋向成熟。考虑以后将手机、电脑联机,操作通过扫描大屏二维码注册使用中、外文数据库,演示检索过程,让新员工有更直观的认识和更深入地参与。

Intraocular lens discoloration secondary to intracameral dye

The use of capsular dyes in cataract surgery helps better visualization of the anterior capsule during capsulorhexis in advanced cataracts.

Jensen

described a series of 11 patients with visually significant crystalline deposits on the IOL surface. During their investigation, the only consistent feature was using Healon GV,a high concentration and high molecular-weight hyaluronate sodium. They suggested that reaction between calcium in the irrigating solutions or the aqueous humor with the phosphate constituents of the ophthalmic viscosurgical device (OVD)is the possible underlying mechanism for formation of these deposits. The crystalline deposits could last for a long time (at least 6mo), especially in sequestration by posterior capsule with significant deterioration of visual acuity (20/40 or worse).More severe crystallization was associated with silicone IOLs. Capsulotomy may be helpful in selected patients. It is advisable that IOL loading should not take place too long prior to implantation into the anterior chamber. Application of the recommended IOL injector by the manufacturer is also beneficial to avoid intraoperative crystalline deposits.

A previous study reported IOL explantation due to permanent blue discoloration by trypan blue dye (0.1%). The IOL was a high water content (73.5%) hydrophilic acrylic lens (Acqua,Mediphacos). The patient presented with dark double vision one week after surgery. Examination showed a decentered dark blue stained IOL. No changes were seen after 40d and the lens was replaced with a PMMA IOL with satisfactory results.Evaluation of the explanted IOL and experimental staining of two unused Acqua IOLs with trypan blue 0.01% and 0.001%was performed. The unused IOLs showed permanent staining even with 100 times more diluted concentration. The blue discoloration was denser in the optic periphery and did not clear after 24h of lens immersion in a balanced salt solution at 37℃ . The analysis demonstrated that staining was much lighter in the hydrated state than a dry state. This IOL is implanted in a dry state and will expand after hydration in the bag. Uptake of the dye might occur in the remaining residual amounts of trypan blue during IOL hydration in the anterior chamber. Reviewing of surgical and clinical charts of the Department of Ophthalmology of the Hospital da Piedade revealed 12 cases of postoperative IOL staining, of which ten were asymptomatic. The authors stated that the Acqua lens is not an appropriate option when using trypan blue dye

.

选取我院2016年5月至2017年5月进行低温等离子辅助下腺样体和扁桃体手术的患儿89例作为本次研究对象,对所有患儿的临床资料进行回顾性分析。

Another study reported corneal edema and IOL blue discoloration after inadvertent utilization of methylene blue instead of trypan blue dye in phacoemulsification. The lens was a silicone IOL (S140NB) which was explanted and analyzed.The surface and internal substance showed permanent staining.Experimental staining of 16 lenses (4 silicone, 4 hydrophobic acrylic, 4 hydrophilic acrylic, and 4 PMMA) was done with immersion in 0.5 mL of methylene blue (1%, 0.1%, 0.01%, and 0.001%). The most intense staining occurred with hydrophilic acrylic IOLs, and also all were permanently stained except PMMA

.

Intraocular lens coating by ointments Penetration of ophthalmic ointments through clear corneal incisions after completion of phacoemulsification was hypothesized by Werner

. They reported eight patients with toxic anterior segment syndrome (TASS), which had an oily film like material/oily bubble in the anterior chamber. All the patients underwent IOL explanation. Also, penetrating keratoplasty was performed in four cases. An oily substance was found coating both surfaces of the IOLs during analysis. Therefore,cataract surgeons should check the wound integrity at the end of surgery

.

Intraocular lens discoloration by povidone iodine

Early hydrophobic silicone IOL opacification by povidone-iodine has been demonstrated in an experimental setting. The IOL staining was seen to be concentration-dependent. The duration of exposure was also determined. The most significant risk is when the povidone-iodine is instilled at the end of surgery.Inadvertent leakage could lead to the entrance of the toxic chemical into the anterior chamber. Complete wound closure is strongly advocated to prevent IOL and corneal endothelial damage by povidone-iodine

.

Breakdown of ocular-blood barrier

One bilateral reversible IOL opacification case has been reported in a woman with a history of diabetic retinopathy and chronic myelogenous leukemia. The patient underwent bilateral phacoemulsification and hydrophilic acrylic IOL (Akreos MI-60) implantation one month before notifying the significant IOL cloudiness on the anterior surface of both lenses. Bilateral intravitreal injection of bevacizumab was done for treating severe cystoid macular edema in the first postoperative month. One week later,clearing the opacity started with nearly complete resolution after two months. Alterations in the ocular blood barrier and increasing vascular permeability secondary to surgery and the underlying diseases (diabetes and leukemia) could affect aqueous humor composition. The pattern of central clearing is compatible with the role of aqueous in dissolving the deposits based on the concentration gradient. In this case, anti-vascular endothelial growth factor injection reversed the haziness

.

Postoperative inflammation

Kim

introduced a 72 years old female for whom a hydrophobic acrylic IOL (Tecnis ZCB00) was implanted during cataract surgery. She presented with significant IOL opacification over the entire anterior surface of the lens, sparing the central region two weeks after surgery. Slit-lamp examination showed mild anterior chamber reaction as well. The frequency of topical corticosteroid eye drop increased. The concentric opacity wholly resolved after four weeks. Two main reasons were discussed. The first is the possibility of temporary growth of lens epithelial cells because of the beginning of opacification from the peripheral optic.Another hypothesis is the presence of an atypical and delayed form of TASS. The accompanying anterior chamber reaction and resolution of clouding after frequent steroid prescription favor inflammatory origin

. Similarly, there is a report in a 68-year-old woman who experienced temporary IOL opacification

.

在超声波检查时发现,桩周围存有缺陷,桩身成形不完整。产生这种现象的原因孔桩护壁不好,浇筑时出现坍塌,还有就是因为混凝土和易性不好,不能很好的流动造成桩底沉淀物在浇筑上涌的过程中没能顺利上升,散落在桩周围造成的。

Miscellaneous

A study by Mehta

described seven to nine thin elongated oval-shaped markings on the posterior surface of Aquafold IOL (model CB F32 UVA, Omni Lens Pvt. Ltd.). The lines were 3-7 mm long parallel to each other and perpendicular to the direction of the lens folding in the cartridge and eventually disappeared after four months. These unusual lines were not compatible with folding marks and they were also uncommon for being inflammatory in origin due to linear configuration and late complete resolution. It has been mentioned that mild secondary calcification of some residual viscoelastic/ethylene oxide as a nidus could be the underlying reason

.

Hilgert

published a case series of four patients who developed silicone IOL opacification on the first postoperative day. The optic was homogenously affected by non-progressive milky gray/yellow opacity resulting in lens explantation in three patients. Analysis of an explanted IOL revealed that the clouding was only observed in a hydrated state and no deposits were found. They explained the theory of IOL contamination after the manufacturing process because the affected lenses were from different lots. Exogenous molecule contaminants(terpenes and ketones) could change the hydrophilicity of the hydrophobic silicone IOL giving rise to the influx of water and early opacification of silicone lenses

.

The IOL should be kept at room temperature before implantation to prevent from fluctuations in the temperature,especially in the winter season and in countries with cold climates. This phenomenon will almost always be spontaneously resolved with no permanent structural change.Accordingly, the ophthalmologists should be aware of the transient nature of this event and avoid unnecessarily removing the implant. Table 1 summarizes reports of intraoperative IOL opacification due to rapid temperature fluctuation

.Crystallization on intraocular lens surface Crystallization at the time of surgery is an uncommon event but can significantly reduce the visual acuity due to the persistence of deposits

. Silicone IOLs are more sensitive for this type of opacification.

Init_SIM300(char* ptr1_at,char* ptr1_code) //SIM300模块初始化

DISCUSSION

Another study mentioned transient homogenous central opacification of a MemoryLens IOL (model CV232, Ioltech)on the first postoperative day, which cleared after a week.Although the exact cause was unknown, the contamination during manufacturing was postulated to be a possible mechanism

.

经检测252件柑橘样品中可溶性固形物平均值12.774%,全部超过优等果标准;总酸量平均值0.733%,91.27%的样品属优等果;固酸比平均值18.535,达到优等果标准的样品占98.02%。总糖平均值7.428%,维生素C平均值2.729 mg/100g。

IOL opacification may be detected during implantation.The most common presumed cause in intraoperative IOL clouding is rapid temperature change. Almost all of these IOLs transferred shortly before implantation into the operating room in subzero temperature. Sudden temperature rise after introduction into the anterior chamber may cause the incorporation of water into the IOL material. Microbubble formation, water vapor consolidation on a cold surface, and subsequent light refraction are also described. The IOL will be clear after several minutes to hours following dehydration.Delayed IOL exchange is recommended in the setting of storage in cold temperature because of the high rate of spontaneous resolution. Taking precautions to IOL storage conditions to prevent from rapid temperature fluctuations is important. It is suggested to store the IOL at room temperature and consider the manufacturer’s guidelines.

In contrast, crystallization of the IOL surface due to the reaction between calcium in the irrigating solutions with the phosphate of the OVD is unlikely to clear spontaneously.Drying out of OVD is another possible cause. It is particularly visually significant with silicone lenses. The surgeons could load IOLs shortly before implantation by using an appropriate injector and irrigate the viscoelastic carefully to avoid this complication. It is advisable to remove the lens if such complications during surgery is encountered. Capsulotomy may also be beneficial in some patients.

目前,影响重合闸成功率的研究多针对更高电压等级的输电网[1-6],对农村配电网领域的研究较少。现在大部分的农村配电网普遍装设了重合闸装置但重合成功率却不高。因此有必要对农村配电网重合闸成功率的影响因素进行深入分析和研究。

Several factors could be involved when a surgeon detects IOL clouding in postoperative visits. We reviewed these cases up to the first month following surgery. It should be mentioned that no definite rule and definition is available regarding the duration of acute IOL opacification. The preoperative manufacturing process is critical. Careful monitoring is required particularly during IOL packaging, disinfection,and storage procedures. Accidental introduction of volatile chemicals such as disinfectants and insecticides into the IOL through vapor-permeable packaging is a likely event that may change the hydrophilicity of the lens material. As a result, IOL hydration could occur and IOL clearance would be affected.It is mainly seen with silicone lenses, which will demonstrate gray-white or brown haze. A pattern of peripheral clearing is described. However, this type of opacity often requires IOL exchange due to its persistence and reduction of vision.

Permanent IOL blue discoloration was reported due to residual amounts of intraocular trypan blue dye. The most vulnerable lenses were hydrophilic acrylic IOLs. Careful irrigation of intracameral dyes is important to avoid IOL staining.Complete wound closure is also essential for preventing from the entrance of povidone-iodine or prescribed ophthalmic ointments into the eye. These are other probable causes of IOL discoloration.

Postoperative inflammation and TASS were implicated in a few cases. The opacity is potentially reversible. Corticosteroids have a leading role in the management.

Regardless to the shape, productive company, material properties, and surface technology of materials, acute IOL discoloration can be occurred in almost all types of IOLs such as hydrophilic acrylic IOL, acrylic hydrophobic IOL,hydrophilic acrylic IOL with a hydrophobic surface, trifocal IOL, silicone IOL, and PMMA IOL

. However,some types of discoloration are more common is some particular types of IOLs. This fact shows that acute IOL discoloration whether intraoperative or early postoperative is relatively unpredictable and should not change the surgery plan or IOL selection. On the other hand, incidence of this event is extremely unremarkable compared to the number of performed cataract surgeries. Also, the role of underlying diseases such as diabetes mellitus and uveitis in acute IOL discoloration is unclear. However, we think unlike late IOL opacifications, this role is not significant since the number of reported cases of acute discoloration with underlying conditions like diabetes mellitus is extremely low.

2009年颁布的《中华人民共和国邮政法》中为快件损坏赔偿问题提供了法律依据。根据新邮政法的相关规定,普遍邮政服务业务范围以外的邮件的损失赔偿,适用有关民事法律的规定,并明确要求快递企业应当在其营业场所公示或者以其他方式公布其损失赔偿办法,以及用户对其服务质量的投诉办法,以保障公众的知情权。“快递企业要加强对消费者合法权益的保护,今后可以采取保价、保险的方法解决赔偿问题,即用户根据寄递物的贵重程度,选择办理相应的保价业务,如发生丢失或损毁,由快递企业依据保价金额进行赔偿。”

Almost all of these mechanisms are theoretical and ophthalmologists may encounter patients with no definable origin for loss of lens clarity. Several variables are involved in decision making for IOL explantation, including the severity and pattern of the opacification, the level of visual dysfunction,patient’s visual demands, other ocular and systemic comorbidities,and observation of any sign of clearance in follow-up visits.In conclusion, most of the acute IOL opacifications could be avoided by taking precautions in manufacturing and storage conditions. Keeping the IOL dry and clean away from rapid temperature fluctuations is advisable. The role of standard surgical procedures and choosing of proper surgical materials should also be considered. Conservative management before IOL explantationis a reasonable approach in many patients.

ACKNOWLEDGEMENTS

Conflicts of Interest: Momenaei B, None; Akbari MR, None;Tabatabaei SA, None; Soleimani M, None; Soleymanzadeh M, None; Fadakar K, None; Alshaheeb A, None; Khazari MM, None; Vaseghi Y, None; Cheraqpour K, None.

1 Neuhann T, Yildirim TM, Son HS, Merz PR, Khoramnia R, Auffarth GU. Reasons for explantation, demographics, and material analysis of 200 intraocular lens explants.

2020;46(1):20-26.

2 Werner L. Intraocular lenses: overview of designs, materials, and pathophysiologic features.

2021;128(11):e74-e93.

3 Pérez-Vives C. Biomaterial influence on intraocular lens performance:an overview.

2018;2018:2687385.

4 Stanojcic N, Hull C, O’Brart DP. Clinical and material degradations of intraocular lenses: a review.

2020;30(5):823-839.

5 Durr GM, Ahmed IIK. Intraocular lens complications: decentration,uveitis-glaucoma-hyphema syndrome, opacification, and refractive surprises.

2021;128(11):e186-e194.

6 Srinivasan S. Intraocular lens opacification: what have we learned so far.

2018;44(11):1301-1302.

7 Yildirim TM, Khoramnia R, Schickhardt SK, Munro DJ, Merz PR,Son HS, Lieberwirth I, Auffarth GU. Variation in intraocular lens calcification under different environmental conditions in eyes with supplementary sulcus-supported lenses.

2020;19:100797.

8 Gurabardhi M, Häberle H, Aurich H, Werner L, Pham DT. Serial intraocular lens opacifications of different designs from the same manufacturer: clinical and light microscopic results of 71 explant cases.

2018;44(11):1326-1332.

9 Wang XC, Wu XM, Dai YH, Huang YS. Intraoperative and postoperative intraocular lens opacifications: analysis of 42545 cases.

2021;2021:1285947.

10 Fernández J, Sánchez-García A, Rodríguez-Vallejo M, Piñero DP.Systematic review of potential causes of intraocular lens opacification.

2020;48(1):89-97.

11 Kanclerz P, Yildirim TM, Khoramnia R. Microscopic characteristics of late intraocular lens opacifications.

2021;145(6):759-767.

12 Park HS, Kim YM, Yang JY. Two cases of intraoperative acute opacification of hydrophilic intraocular lens.

2018;59(10):974.

13 Tyagi P, Shah N, Jabir M. Intraoperative clouding of a posterior chamber intraocular lens.

2011;31(6):483-484.

14 Zhang T, Li SW, Liu C, Zhao RH, Chang CH, Han N. Acute clouding of a trifocal intraocular lens with spontaneous resolution: a case report.

2019;19(1):208.

15 Wang Q, Yildirim TM, Schickhardt SK, Łabuz G, Khoramnia R, Merz PR, Son HS, Munro DJ, Friedmann E, Auffarth GU. Quantification of the

predisposition to glistening formation in one manufacturer’s acrylic intraocular lenses made in different decades.

2021;10(1):165-174.

16 Yildirim TM, Schickhardt SK, Wang Q, Friedmann E, Khoramnia R,Auffarth GU. Quantitative evaluation of microvacuole formation in five intraocular lens models made of different hydrophobic materials.

2021;16(4):e0250860.

17 Gutierrez L, Rodríguez P, García DA. Intraoperative Opacification of a hydrophilic acrylic with hydrophobic surface IOL with spontaneous resolution in 24 hours.

2013;29(5):360-362.

18 McKibbin M, Seemongal-Dass RR, Atkinson PL. Transient fogging of acrylic (AcrySof) intraocular lenses.

(

) 1999;13(Pt 5):672-673.

19 Omar O, Pirayesh A, Mamalis N, Olson RJ.

analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel packaging.

1998;24(1):107-113.

20 Helvacı S. Acute opacification of hydrophobic acrylic intraocular lens during implantation: result of temperature variation.

2015;78(4):267.

21 Sonbolestan SA, Abtahi ZAS. Transient intraocular lens opacification during phacoemulsification surgery.

2018;31(3):342-344.

22 Liu Q, Zhang SH, Wang XG, Cao WF, Jia YD. Acute clouding of trifocal lens during implantation: a case report.

2017;17(1):242.

23 Danese C, Calabresi R, Lanzetta P. Transient clouding of a sutureless scleral fixated hydrophilic intraocular lens with spontaneous resolution: a case report and

experimental test.

2021;12(1):169-173.

24 Lee YJ, Han SB. Time course of acute reversible clouding of the hydrophilic intraocular lens.

2021;128(9):1311.

25 Ota I, Miyake G, Asami T, Miyake K. Steam-like clouding observed on anterior surface of intraocular lens developed soon after implantation.

2018;11:172-175.

26 Jensen MK, Crandall AS, Mamalis N, Olson RJ. Crystallization on intraocular lens surfaces associated with the use of Healon GV.

1994;112(8):1037-1042.

27 Olson RJ, Caldwell KD, Crandall AS, Jensen MK, Huang SC.Intraoperative crystallization on the intraocular lens surface.

1998;126(2):177-184.

28 Hickman MS, Werner L, Mamalis N, Sung E, Goldstein D, Vroman DT, Pandey SK. Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits.

(

) 2006;20(9):1054-1060.

29 Faschinger CW. Plastic exfoliations from the cartridge after implantation of a hydrophilic acrylic lens without viscoelastic material.

2002;28(1):8-9.

30 Nikrooyan I, Anderson JE. Early opacification and subsequent

clearing of a silicone intraocular lens.

2011;37(5):323-325.

31 Koch DD, Heit LE. Discoloration of silicone intraocular lenses.

1992;110(3):319-320.

32 Ziemba SL. Silicone intraocular lens implant discoloration in humansreply.

1991;109(7):913-915.

33 Hilgert CR, Hilgert A, Höfling-Lima AL, Farah ME, Werner L. Early opacification of SI-40NB silicone intraocular lenses.

2004;30(10):2225-2229.

34 Tanaka T, Saika S, Hashizume N, Ohnishi Y. Brown haze in an Allergan SI-40NB silicone intraocular lens.

2004;30(1):250-252.

35 Werner L, Dornelles F, Hilgert CR, Botelho F, Conte PF, Rozot P,Andrenyak DM, Mamalis N, Olson RJ. Early opacification of silicone intraocular lenses: laboratory analyses of 6 explants.

2006;32(3):499-509.

36 Elgohary M, Zaheer A, Werner L, Ionides A, Sheldrick J, Ahmed N.Opacification of array SA40N silicone multifocal intraocular lens.

2007;33(2):342-347.

37 Dhoot DS, Flaxel CJ. Early opacification and subsequent clearing of a MemoryLens intraocular lens.

2007;33(4):743-745.

38 Ozbek Z, Saatci AO, Durak I, Gunenc U, Ergin MH, Cingil G.Staining of intraocular lenses with various dyes: a study of digital image analysis.

2004;218(4):243-247.

39 Werner L, Apple DJ, Crema AS, Izak AM, Pandey SK, Trivedi RH,Ma LW. Permanent blue discoloration of a hydrogel intraocular lens by intraoperative trypan blue.

2002;28(7):1279-1286.

40 Stevens S, Werner L, Mamalis N. Corneal edema and permanent blue discoloration of a silicone intraocular lens by methylene blue.

2007;38(2):136-141.

41 Werner L, Sher JH, Taylor JR, Mamalis N, Nash WA, Csordas JE,Green G, Maziarz EP, Liu XM. Toxic anterior segment syndrome and possible association with ointment in the anterior chamber following cataract surgery.

2006;32(2):227-235.

42 Goel S, Kolli LR, Desai SP, Kumar A, Gauba V, Jayamanne GR.Povidone iodine causes opacification of silicone intraocular lens implants.

2008;86(7):773-777.

43 Park CY, Chuck RS. Reversible opacification of a hydrophilic acrylic intraocular lens.

2012;38(1):166-169.

44 Kim DJ, Chuck RS, Lee JK, Park CY. Reversible opacification of hydrophobic acrylic intraocular lens- two cases report.

2017;17(1):111.

45 Quigley C, Ashraf MO, Manning S. Reversible opacification of a hydrophobic acrylic intraocular lens.

2020;46(2):319.

46 Mehta A. Unusual markings on an intraocular lens postoperatively.

2012;60(3):241-242.

47 Iwase T, Sugiyama K. Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure.

2007;33(2):329-332.

48 Parkin B, Pitts-Crick M. Opacification of silicone intraocular implant requiring lens exchange.

(

) 2000;14 Pt 5:794-795.

49 Ma ST, Yang CM, Hou YC. Postoperative intraocular lens opacification.

2018;8(1):49-51.

50 Grzybowski A, Markeviciute A, Zemaitiene R. A narrative review of intraocular lens opacifications: update 2020.

2020;8(22):1547.

51 Weindler JN, Łabuz G, Yildirim TM, Tandogan T, Khoramnia R,Auffarth GU. The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens.

2019;45(7):1020-1025.

52 Mackert M, Muth DR, Vounotrypidis E, Deger C, Goldblum D,Shajari M, Hasler PW, Priglinger S, Wolf A. Analysis of opacification patterns in intraocular lenses (IOL).

2021;6(1):e000589.

53 Bang SP, Moon K, Lee JH, Jun JH, Joo CK. Subsurface calcification of hydrophilic refractive multifocal intraocular lenses with a hydrophobic surface: a case series.

2019;98(50):e18379.

54 Tandogan T, Auffarth GU, Son HS, Merz P, Choi CY, Khoramnia R.

-

glistening formation in six different foldable hydrophobic intraocular lenses.

2021;21(1):126.

55 Łabuz G, Knebel D, Auffarth GU, Fang H, van den Berg TJ, Yildirim TM, Son HS, Khoramnia R. Glistening formation and light scattering in six hydrophobic-acrylic intraocular lenses.

2018;196:112-120.

56 Costa JF, Bompastor-Ramos P, Marques M, Henriques J, Póvoa J, Lobo C, Alió JL, Werner L, Murta J. Large-scale opacification of a hydrophilic/hydrophobic intraocular lens.

2020;30(2):307-314.

57 Yildirim TM, Fang H, Schickhardt SK, Wang Q, Merz PR, Auffarth GU. Glistening formation in a new hydrophobic acrylic intraocular lens.

2020;20(1):186.